Root Cause Failure Analysis for Rotating Equipment
Author
Hisham Abdalla
Date Published

Disclaimer: Research and analysis by the engineering team. The worked example is a hypothetical. Sources referenced below.
Root cause failure analysis, or RCFA, is a structured investigation that traces a failed machine back through the physical mechanism, the human action and the management condition behind it. The aim is a fix that removes the reason for the failure, not only the broken part. On rotating equipment it starts at the failed component, because the metal, the oil and the data logged at the time hold the evidence. A new bearing inherits the cause of the last one unless someone finds that cause first.
This article covers when to start an RCFA, how to protect the evidence, how to read fractures and wear, which method suits which failure, and how to write actions that last. It ends with one hypothetical case, from a wiped bearing surface to a management cause.
When Should You Trigger a Root Cause Failure Analysis?
Not every failure deserves a team. A bearing that has run to the end of a long life needs only a note in the history. These do deserve one:
A repeat failure. The same part, the same machine or the same fault twice in a short time means the first repair did not touch the cause.
A failure well before expected life. Something changed: the duty, the lubricant, the alignment, the installation.
A serious consequence. Injury risk, a fire, an environmental release or a long outage, and also a near miss that could have had one.
A failure nobody can explain. If operators, maintainers and the vendor all have different stories, you need the evidence to decide between them.
Write the trigger down before the failure happens. Nobody wants that argument in the middle of an outage.
Preserve the Evidence Before Anyone Cleans It
The first hours decide if the cause can ever be known. The UK Health and Safety Executive's investigation guide starts with emergency action and making the area safe, then preserving the scene and noting the people, equipment and witnesses involved (HSE HSG245). Once a machine is safe, that means more specific habits.
Photograph before touching. Take wide and close images of the failed part in place, with a scale, before anything is removed.
Do not clean fracture or wear surfaces. No wire brush, no solvent, no fitting two broken halves together to see if they match. Tag the part, keep it dry and wrap each piece separately.
Take the fluids first. Sample the oil before the system is drained, and cut open the filter. Both hold wear debris that will not be there after the flush.
Export the data. Control system trends and alarm logs get overwritten. Save them with the sequence of events before anyone resets anything.
Record as-found positions. Clearances, alignment, valve positions and breaker states, exactly as they were.
Talk to the people early. Operators and maintainers remember details that never reach the logbook. Ask what they saw, not what they think caused it.
Stop a damaged machine as early as it is safe to do so. A bearing that runs on until it seizes can destroy the features that would have told you why it failed.
Reading Fractures and Wear
A broken shaft, bolt or blade carries the story of how it failed, if the surface survives. Course notes by Erik Mueller for The Minerals, Metals and Materials Society set out the main patterns (TMS, Failure Analysis and Fracture).
Fatigue. A crack that starts and grows under cyclic stress below the material's tensile strength. The surface is smoother and possibly discoloured, with no gross deformation next to it and no shear lip in the fatigue zone. Crack arrest marks, often called beach marks, show where growth paused. Ratchet marks appear when cracks start at several points. The fracture ends in a rougher final overstress region where the remaining section gave way.
Ductile overload. The part stretched before it broke. Look for necking, shear lips at the edges and a dull grey fracture surface.
Brittle overload. No gross deformation, a fracture plane at 90 degrees to the tensile stress and a rough surface. Chevron or radial marks point back toward the origin.

Surface features that separate a fatigue fracture from ductile and brittle overload. Photograph before touching, and confirm against service history. Source: TMS course notes, Failure Analysis and Fracture (Mueller); MIMAH engineering practice.
Wear and corrosion read differently. Abrasive wear scores the surface along the direction of sliding. Adhesive wear smears and tears material from one surface onto the other. Corrosion leaves pits, deposits and discolouration.
The surface suggests a mechanism. It does not settle the question. Confirm it against the service history, hardness, material verification and, where it matters, metallography. For a wiped journal bearing the clues are different, and our article on babbitt bearing repair covers how babbitt wears and fails.
5 Whys, Fishbone or Fault Tree?
Three methods do most of the work, and each fits a different kind of failure.
5 whys. Ask why a failure happened, then ask why of the answer, until the answer is a condition in the system. The Institute for Healthcare Improvement describes the technique and attributes it to Taiichi Ohno of Toyota, with two cautions: a problem may have more than one root cause, and people who see different parts of the system give different answers (IHI Patient Safety Essentials Toolkit). It suits a single clear chain.
Fishbone diagram. Also called a cause and effect or Ishikawa diagram, it sorts possible causes under headings. The same IHI toolkit lists materials, methods, equipment, environment and people, and on a machine we would add measurement. It is good at the start, with a mixed group, because it stops the team fixing on the first idea. It lists hypotheses and proves none of them.
Fault tree. NASA's handbook describes it as a deductive method. It begins with an undesired top event and works down through AND and OR gates to the basic events that could cause it, and minimal cut sets show the smallest combinations that are enough (NASA, Fault Tree Handbook with Aerospace Applications). Use it when several things had to line up, such as a protection that failed and a demand that arrived.
Our view: open with a fishbone, build a fault tree for anything serious, and use 5 whys to write up each branch. Used alone on a complicated event, 5 whys tends to follow the first plausible chain and stop.

Which root cause method fits which failure. Source: IHI Patient Safety Essentials Toolkit; NASA, Fault Tree Handbook with Aerospace Applications; MIMAH engineering practice.
Physical, Human and Latent Causes
Every failure sits on three levels of cause.
Physical cause. The mechanism in the part: the film that collapsed, the crack that grew, the particles that scored the surface.
Human cause. The action or omission that let it happen: a calibration not done, a test not run, a procedure followed exactly as written but written wrongly.
Latent cause. A condition in the system that was waiting: no one owns the task, no one reviews the procedure, the schedule never included it.
The HSE guide makes the same split as immediate, underlying and root causes, and notes that root causes are generally management, planning or organisational failings. It also warns that dealing only with the immediate cause gives a short-term fix. Look for the system reason a person acted as they did. HSE wants investigations run with prevention in mind and no blame placed.
A Worked Example: From a Wiped Bearing to a Management Cause
This is a hypothetical. Suppose a 10 MW steam turbine generator trips on a grid disturbance and coasts down. On inspection, the babbitt on the No. 2 journal bearing is smeared in the loaded zone and the journal is discoloured.
The evidence. Before anything is cleaned, the team photographs the bearing, takes oil from the tank and bearing header, and cuts open the filter. They export the trip sequence and the bearing metal temperature trace. Oil analysis shows no water and normal particle counts, which argues against contamination. Vibration trends were flat for the previous month, which argues against oil whirl. Alignment records are within limits. The temperature trace rises sharply during the coast down, not before it.
Why was the bearing wiped? The oil film collapsed during coast down. That is the physical cause.
Why did the film collapse? As the rotor slowed, the shaft-driven oil pump lost pressure. The disturbance had taken out the AC supply to the auxiliary pump, and the DC emergency pump that should have taken over did not start.
Why did it not start? The pressure switch that calls the DC pump had drifted until it would act only below the pressure at which the bearing starves.
Why was the drift never found? The Munich Re white paper on lube oil protection notes that in some cases pre-start tests do not fully prove the pressure switch, and recommends supplemental testing or calibration in the maintenance schedule. It also describes a weekly pressure drop test that proves both the pump and the switch (Munich Re, Lube oil protection). In this plant the weekly check started the pump by hand and never tested the switch.
Why did the check stop at the pump? The procedure was copied from an older machine, and after a reorganisation nobody owned the protection tests or reviewed the procedure. That is the latent cause.

A hypothetical wiped bearing traced from the surface back to a management cause, and the stronger action that removes it. Source: MIMAH engineering practice; Munich Re, Lube oil protection systems and common failure modes; IHI Patient Safety Essentials Toolkit.
The physical cause is the starved bearing. The human cause is a switch that was never calibrated or tested. The latent cause is a protection system with no owner. Replacing the bearing and retraining the operators would have left the third cause untouched.
Corrective Actions That Stick
The less an action relies on someone remembering, the stronger it is. The action hierarchy in the IHI toolkit, based on tools from the US Veterans Affairs patient safety centre, ranks actions this way. Stronger actions are physical changes, forcing functions, simpler processes and standardised equipment. Intermediate actions include redundancy, software changes and checklists. Weaker actions are double checks, warnings, new policies and training, which the hierarchy says are unlikely to be enough when used alone. It asks for at least one stronger or intermediate action against each cause, an owner and a date for each.
Applied to the example, the actions might be these.
Stronger. A start permissive that blocks rolling the turbine until the control system has proved the DC pump starts on simulated low pressure.
Intermediate. Two-out-of-three voting on the pressure sensing for each pump, an arrangement Munich Re describes as common, and a protection test list with a named owner and a calendar.
Weaker. Revise the procedure and retrain the crews. Do it, but never alone.
Then add a check that the actions worked: the next three test results, and a review six months on.
What a Good RCFA Report Contains
Event summary and scope. What failed, when, with what consequence, and what the investigation covers.
Timeline. Sequence of events with the data that supports each step.
Evidence list. Photographs, parts, samples, records and interviews, with where each is kept.
Analysis. The method used, the causes considered and why each was kept or ruled out.
Causes at three levels. Physical, human and latent, each stated as a cause and effect sentence.
Actions. Each with strength, owner, date and how success will be measured.
Wider check. Which sister machines share the same weakness. Our guides to steam turbine failures, condition monitoring and preventive versus predictive maintenance help decide what to look at. Borescope inspection can look inside without opening a casing, and dynamic balancing matters when vibration is part of the story.
Do It Yourself or Bring in Help?
Run the analysis in-house when the evidence is in hand, the trigger is clear and someone with authority to change the system sits on the team. Bring in independent help when the owner of the system is part of the cause, when the failure needs a metallurgical laboratory, or when the maker and the plant disagree about what happened.
MIMAH's industrial engineering team provides root cause analysis and performance diagnostics for turbines and rotating equipment, independent of any one equipment maker. If you have a failed part on the bench, or a machine that keeps failing the same way, keep the evidence as it is and get in touch.