Dynamic Balancing of Rotors: Grades, Methods and Field Balancing

Author

Hisham Abdalla

Date Published

Illustration of a rotor shaft with two round discs resting on two bearing blocks, a small gold marker on one disc rim, a curved cyan arrow for rotation and a small engineer beside it

Disclaimer: Research and analysis by the engineering team. Sources referenced below.

Dynamic balancing means measuring a rotor's unbalance and correcting it, usually in two planes, until what is left is below a permissible limit. ISO 21940-11 sets that limit from a balance quality grade, G, and the sum is short: permissible residual unbalance in g·mm equals 9,549 × G × rotor mass in kg ÷ speed in rpm.

That formula, and the habit of specifying a grade and a speed instead of "balanced", is most of what a plant manager needs to judge a balancing job. Below, the formula is worked through a hypothetical rotor, followed by shop methods and a field balance with trial weights, step by step. The basics of what unbalance does to bearings are in our shaft alignment and balancing guide.

Static, Couple and Dynamic Unbalance: When One Plane Is Enough

ISO 21940-11 splits a rotor's unbalance into two parts, the resultant unbalance and the resultant couple (moment) unbalance, because they act differently on the bearings and on the machine's vibration. In simple terms, static unbalance is the first alone and couple unbalance is the second alone. Dynamic unbalance is both together, shown as one unbalance vector in each of two planes, and it is the general case.

One correction plane is enough when only the resultant unbalance is out of tolerance. The standard names single-disc rotors as the typical case, provided the bearings are far enough apart, the disc runs with little axial runout and the correction plane is well chosen. A fan wheel or a short turbine wheel can fit that description.

Everything else needs two planes. The rotor must also be turning during the measurement, because a stationary rotor hides the couple unbalance, which is why a rotor that rests level on knife edges can still shake at speed. Corrections go where material can be added, removed or moved, which is often not the plane where the tolerance is set.

The current text is ISO 21940-11:2016 with its 2022 amendment. It replaced ISO 1940-1:2003, the older number that many drawings still quote. The free preview pages of the 2016 edition cover the scope, how unbalance is represented and the reasoning behind the grades. They stop before the grade table and the allocation clauses, so read those in a full copy, amendment included.

How Much Unbalance Is Allowed: ISO 21940-11 Balance Grades

For rotors of the same type, the permissible specific unbalance, e, which is the permissible unbalance divided by the rotor mass, varies inversely with service speed. So e multiplied by the angular velocity is constant, and that constant, in mm/s, is the balance quality grade G.

Angular velocity is 2π × n ÷ 60 rad/s for a speed n in rpm. Solve for e in micrometres, which is numerically the same as g·mm per kg:

e = 1,000 × G × 60 ÷ (2π × n) = 9,549 × G ÷ n

Multiply by the rotor mass m in kg and the permissible residual unbalance is U = 9,549 × G × m ÷ n in g·mm. The same formula appears in Balance Quality Requirements of Rigid Rotors, a paper by the balancing machine maker IRD Balancing on the older ISO 1940/1 text. The grade examples here come from the table it reprints. Later editions word that table differently, so take the grade for your own rotor from your copy of the standard.

Grades step by a factor of 2.5. G 6.3 covers fans, pump impellers, flywheels and general machinery parts. G 2.5 covers gas and steam turbines, rigid turbo-generator rotors, turbo-compressors and turbine-driven pumps. G 1 covers grinding machine drives.

At 3,000 rpm, the specific unbalance allowed is 20.1 g·mm per kg at G 6.3, 8.0 at G 2.5, and 3.2 at G 1. Halve the tolerance every time the speed doubles.

Take a hypothetical 700 kg steam turbine rotor with rigid behaviour, running at 3,000 rpm and specified to G 2.5.

Specific unbalance: e = 9,549 × 2.5 ÷ 3,000 = 7.9575 g·mm per kg, which is 7.96 µm.

Permissible residual unbalance: U = 7.9575 × 700 = 5,570 g·mm for the whole rotor. If the same rotor ran at 6,000 rpm the grade would allow 2,785 g·mm.

Three ISO balance quality grades with example rotors and the specific unbalance each allows at 3,000 rpm: G 6.3 allows 20.1 g mm per kg, G 2.5 allows 8.0 and G 1 allows 3.2

Balance quality grades and the specific unbalance each allows at 3,000 rpm, from U = 9,549 x G x m / n. Source: IRD Balancing, 'Balance Quality Requirements of Rigid Rotors' (table from the older ISO 1940/1); ISO 21940-11:2016.

Sharing the Tolerance Between Two Planes

ISO 21940-11 defines U as the total tolerance in the plane of the centre of mass, so a two-plane job has to share it out. The contents page shows where: clause 7 allocates U to the tolerance planes, with limits for inboard and outboard rotors, and clause 8 carries those tolerances to the correction planes. That text is paywalled, so the rules below follow the IRD paper. Check them against clause 7 of your copy.

If the centre of mass sits midway between the planes, each plane gets half. For our rotor that is 5,570 ÷ 2 = 2,785 g·mm per plane, which at a 350 mm radius is a residual of about 8 g in each plane.

If the centre of mass is nearer one plane, that plane takes the larger share, in proportion to the distance from the other. IRD writes this rule for correction planes, while the standard normally takes the bearing planes as its reference planes for tolerances, so the example uses bearing distances. Suppose the bearings are 1,800 mm apart and the centre of mass is 800 mm from the left bearing and 1,000 mm from the right. The left share is 5,570 × 1,000 ÷ 1,800 = 3,094 g·mm, and the right share is 5,570 × 800 ÷ 1,800 = 2,476 g·mm. That is 55.6 and 44.4 percent, and the two add back to 5,570. IRD adds a limit: neither share should fall below 30 percent or exceed 70 percent of the total. If it does, treat the rotor as a narrow or overhung one and allocate static and couple parts instead.

Two further cases need the standard itself: rotors with correction planes outside the bearings, which have a reduced total, and overhung or narrow rotors, which are allocated as a static part and a couple part.

Shop Balancing: Low-Speed Machines and High-Speed Facilities

The standard calls a rotor rigid when its flexing under unbalance can be neglected, against the agreed tolerance, at any speed up to maximum service speed. For those, a balancing machine at low speed is the normal route, with the rotor turning on the machine's own bearings. Where a very small specific unbalance is required, the standard notes that the rotor may need balancing in its own service bearings, or even assembled in its own housing at service temperature.

That definition has no speed ratio in it. One practitioner does offer a number. Dennis Shreve, in an article on field balancing fundamentals, says a rigid rotor typically runs below 70 percent of its first critical speed. Treat that as one engineer's screening figure, not a limit. I would use it to decide what to check next, then go to the critical speed data for the machine.

A rotor that does flex comes under ISO 21940-12. It says rotors with flexible behaviour normally need multiplane balancing at high speed, though under certain conditions they can be balanced at low speed, and an informative annex covers how to tell rigid behaviour from flexible.

The shop's target should be tighter than the tolerance. The standard's introduction says it distinguishes the permissible residual unbalance from the lower values the balancing process aims for, because the measurement has its own errors.

Ask for the certificate to say: the grade, the service speed, the planes, the tolerance per plane, the residual per plane, and the balancing machine used. A certificate that only says "balanced" cannot be checked by anyone.

Field Balancing With Trial Weights, Step by Step

Field balancing corrects the rotor in its own bearings, with its own supports and temperature. ISO 21940-13:2012, described by BSI, covers when in situ balancing is appropriate, the instruments needed, safety, and the reporting and records. It can serve as a basis for a contract, but it does not give the calculation of correction masses. The calculation is below, as a single-plane balance of our hypothetical rotor with one correction plane at a 350 mm radius and one reading at one bearing. A real rotor of that length would more likely need two planes, which the last paragraph of this section covers.

Check the rotor first. The vector method assumes a rigid rotor and a linear response, so confirm those and that the vibration is mostly once per revolution. Shreve gives practical tests: the 1X component should be more than 80 percent of the overall level, and the radial readings should be similar in amplitude with about 90 degrees of phase between vertical and horizontal. He is writing mainly about rolling-element machines. On journal bearings the two directions can differ in stiffness, so treat the amplitude match as a guide.

Confirm that the readings repeat. Shreve's conditions are the same speed and the same radius on every run, amplitude stable within 5 percent and phase within 3 to 5 degrees. If readings wander more than that, balancing will chase noise.

Make it safe. Lock out and tag the machine each time a weight goes on or comes off. A trial weight is a loose part at speed, so fix it positively, and keep people out of line with its plane during the run.

Original run. Measure 1X amplitude and phase at the bearing. In our example the original reading is O = 50 µm peak to peak at 30 degrees.

Size the trial weight. Converted to metric units, Shreve's trial weight formula gives a weight whose centrifugal force is about 10 percent of the rotor's weight. For our 700 kg rotor, that force is 0.10 × 700 × 9.81 = 687 N. At 3,000 rpm, ω = 314.2 rad/s, so ω² = 98,696. At a 350 mm radius the trial mass is 687 ÷ (98,696 × 0.35) = 0.0199 kg, about 20 g. As a check, Acoem's guidance is that the weight should change the amplitude by about 30 percent or the phase by about 30 degrees. The force on that 20 g is 691 N at 3,000 rpm and a quarter of that, 173 N, at 1,500 rpm. Shreve says a rigid rotor can be balanced at a lower, safer speed if needed, but every run must then be at that speed.

Trial run. Fit the 20 g at the reference mark, 0 degrees, at 350 mm. The new reading is O + T = 45.8 µm at 79 degrees. The amplitude barely changed, but the phase moved 49 degrees, which clears the check.

Do the vector arithmetic. The method follows Acoem's vector approach to single-plane balancing. Split each reading into two components, amplitude × cosine of the angle and amplitude × sine of the angle. The effect of the trial weight, T, is the new reading minus the original.

O = 50 at 30° = (43.30, 25.00). O + T = 45.8 at 79° = (8.74, 44.96). So T = (8.74 − 43.30, 44.96 − 25.00) = (−34.56, 19.96), which is 39.9 µm at 150°.

The influence coefficient is that effect divided by the trial weight: 39.9 µm ÷ 20 g = about 2.0 µm per g, at 150°. To cancel the original, the correction must produce the opposite of O, which is 50 µm at 210°. The correction weight is 50 ÷ 2.0 = 25 g, and its angle is 210° − 150° = 60° from the trial weight position.

Fit the correction. Remove the trial weight and fit 25 g at 60 degrees from its position, at the same 350 mm radius. That sum counts weight angles and phase angles in the same direction. Instruments differ, and Shreve's own example has the phase reading move the opposite way to the weight, so settle the direction before the first run and keep it. Fit our 25 g 60 degrees the wrong way and the 50 µm climbs to about 87 µm.

Check the result against the grade. With one correction plane, the whole limit applies to that plane. Suppose the final run reads 6 µm. At 2.0 µm per g, that is 3 g, or 3 × 350 = 1,050 g·mm of equivalent unbalance, which is 19 percent of our 5,570 g·mm limit. The original unbalance was 25 g × 350 mm = 8,750 g·mm, which was 157 percent of the limit. Treat this as an estimate, because the 1X reading also includes runout and any non-unbalance sources, and confirm with a trim run if the number is close.

Two-plane field balancing follows the same logic with three runs, original, trial weight in plane one, trial weight in plane two, and a two-by-two set of influence coefficients that includes the effect of each plane on the other bearing. Instruments do that arithmetic for you.

A single plane field balance worked through: original reading, 20 g trial weight, trial reading, vector solution of 25 g at 60 degrees, and a final check against the 5,570 g mm limit

A hypothetical single plane field balance on a 700 kg rotor at 3,000 rpm, with the G 2.5 limit of 5,570 g·mm. Source: MIMAH engineering practice; method after Acoem and Shreve.

Why Balancing a Misaligned or Loose Machine Wastes the Day

ISO 21940-11 itself says the vibration in service can come from sources other than unbalance. Shreve lists dirt build-up, shaft instability, looseness, a bent or cracked shaft, resonance, foundation looseness, pulley eccentricity and misalignment as other causes of high 1X vibration, and warns against trying to balance out an underlying problem. Weights go on, the readings do not settle, and the cause is still there.

Check alignment and soft foot first, as in our shaft alignment and balancing guide. Rule out looseness and a resonance near running speed with a run-up and coast-down. Look at the spectrum and the phase, using our vibration analysis guide, to decide whether the fault is unbalance at all. Then judge the result against the limits in our guide to ISO 20816 vibration limits.

A rotor that needs balancing again and again has a cause that is still active: build-up, erosion or a developing crack. A sudden step in the 1X amplitude or phase on a turbine suggests that mass has left the rotor, such as a shroud segment. Look inside before adding weights, and our article on turbine borescope inspection explains what that look can and cannot show.

Five checks before balancing: alignment and soft foot, looseness and resonance, whether the vibration is unbalance at all, whether the readings repeat, and whether the unbalance keeps coming back

Checks that decide whether balancing will work. Source: Shreve, 'Fundamentals for Successful Field Balancing' (Reliabilityweb); ISO 21940-11:2016, clause 4.1.

What to Specify, and What to Do Next

Write the balance requirement as a sentence a stranger could check: "Balance to G 2.5 per ISO 21940-11 at 3,000 rpm, rotor mass 700 kg, residual unbalance not to exceed 5,570 g·mm in total, shared between planes as the standard's allocation rules require." Ask for the certificate to match. For a field balance, ask for the starting readings, trial weights, final readings and the weights left on the rotor, so the next crew has a baseline.

MIMAH's rotating equipment team is independent of any one OEM, and our work includes performance diagnostics and root cause analysis on turbines and other rotating equipment. If you have a vibration problem you cannot yet call unbalance, or a balance specification you want checked before it goes into an overhaul order, get in touch.