Steam Turbine Labyrinth and Gland Seals: How They Work and Why They Wear
Author
Hisham Abdalla
Date Published

Disclaimer: Research and analysis by the engineering team. Sources referenced below.
A labyrinth seal is a non-contact seal. A row of thin fins, called teeth, sits a fraction of a millimetre from the rotor and makes steam pass through a series of narrow gaps and small chambers. Each gap throttles the steam, so the pressure falls in steps and only a little steam gets through. A gland seal is the seal where the shaft leaves the casing, most often a labyrinth, and it works with a steam system that keeps steam in and air out.
Because the seal never touches the shaft, it should last. In practice it does not, because rubs at start-up open the clearance and the leakage grows quietly. Below is how the seal works, how the gland steam system uses it at each end of the turbine, the variants from carbon rings to brush seals, how failing seals show up, and how to measure and order a replacement.
How a Labyrinth Seal Works Without Touching the Shaft
Steam wants to flow along the shaft from high pressure to low. The seal puts a long series of restrictions in its way. At each tooth the steam is squeezed through the gap and speeds up, so pressure is traded for velocity. In the chamber behind the tooth the jet slows and its energy is lost to turbulence. Repeat that across many teeth and the pressure comes down in small steps, with only a small flow left at the end. In the high pressure glands of one large plant design, for example, steam passing the shaft seals is throttled until it is only slightly above atmospheric pressure, according to the U.S. EPR safety analysis report.
Two things mainly set the leakage. A paper from the Karlsruhe Institute of Technology on rubbing in labyrinth seals names them as the gap between the sealing tip and the stator, and the pressure ratio across the seal. The pressure ratio is fixed by the machine. The gap is the part that changes with wear.
A 2000 article by Mary Foley of the seal supplier TurboCare, published in Modern Power Systems, gives the standard labyrinth packing radial clearance as about 0.010 to 0.025 in, which is 0.25 to 0.64 mm. Take a hypothetical 250 mm shaft with a radial clearance of 0.40 mm. The annular leak path under one tooth is π x 250 mm x 0.40 mm = about 314 mm². If rubs open the clearance to 0.80 mm, the same tooth leaves a path of π x 250 mm x 0.80 mm = about 628 mm². The area has doubled, and as a first estimate the leakage through that ring rises by about the same proportion at the same pressure drop.
Design practice allows for wear. The gland sealing system in that same report is sized to pass flow to and from all its glands assuming 1.5 to 2 times the normal clearances.
Tip, Root, Interstage and Gland Seals: Where Each One Sits
A steam turbine has labyrinth seals in more places than the shaft ends, and the position matters when you read a clearance record.
Tip seals. They stop steam passing over the top of the rotating blades without doing work.
Root seals. They sit at the base of the blades, stopping shaft leakage entering the main flow and main flow leaking into the space between the diaphragm and the disc.
Interstage shaft seals. These sit between the shaft and the inner diameter of each diaphragm, where steam would otherwise slip past the nozzles.
Gland seals. They sit where the shaft passes through the casing at each end, and on the stems of the main steam stop and control valves. The design report says the system exists to keep steam from escaping at those points and to keep air from leaking into the low pressure glands.
Steam that takes any of these routes does less work than steam that stays in the blade path. That is why a seal that never breaks still earns a place in the outage scope, as our guide to steam turbine overhaul sets out.
How the Gland Steam System Works at the High and Low Pressure Ends
The two ends of a condensing turbine have opposite problems, and the gland steam system handles each. The details below come from the U.S. EPR Final Safety Analysis Report, section 10.4.3 on the turbine gland sealing system. It describes a large plant, and a small industrial turbine will have a simpler version, but the logic is the same.
High pressure end. Steam inside is above atmospheric pressure and wants to escape. The shaft seals throttle it to slightly above atmospheric, and the leak-off goes to a sealing steam header common to the turbine's shaft seals.
Low pressure end. Steam inside is under vacuum, so the problem is air coming in. The low pressure shaft seals are fed sealing steam from the header, which keeps air out of the turbine and the condenser.
Start-up and low load. The high pressure seals leak too little to supply the header at that point, so auxiliary steam is admitted through seal steam supply valves to hold the header pressure.
Normal load. Enough steam escapes through the high pressure seals to supply the low pressure seals. The surplus at higher loads is dumped to the main condenser through the seal steam leak-off valve.
Outer leak-off. A second steam space sits between the sealing steam and the atmosphere. Gland steam and any air that enters it are drawn off by exhausters through the gland steam condenser, which is cooled by condensate. The exhausters hold a slight vacuum in that condenser, and the condensate drains to the main condenser through a steam trap.
The report lists the parameters watched in service: steam seal header temperature and pressure, exhauster vacuum, gland condenser outlet temperature and gland condenser pressure. They are also the first things to check when something looks wrong.

What the gland steam system does at each end of a condensing steam turbine. Source: U.S. EPR Final Safety Analysis Report, section 10.4.3 (NRC).
Carbon Ring Seals on Small Turbines
General purpose turbines often seal the shaft with carbon rings, not fin labyrinths. Peter Zanini of the seal supplier Inpro/Seal, writing in Pumps & Systems in 2016, says carbon rings remain the standard in general purpose steam turbine sealing. Each ring is built from three segments held together by a garter spring.
The weakness is wear. Wear at the inner bore of the ring gradually opens the shaft clearance and the steam leakage, and rings can break. Zanini is selling alternatives, so weigh his claims accordingly, but the consequences he lists are ones any operator can check: more steam lost, oil contamination that degrades bearings, and higher operating temperatures.
My view is that carbon rings are consumables and should be treated as such. Keep a spare set per turbine end, change them at a planned outage, and look at the shaft or sleeve under the ring each time. A new ring on a grooved or scored surface will not seal. A leaking ring left in service also puts water into the oil. Our guide to turbine lube oil analysis shows how to catch that, and our article on babbitt bearing repair covers how to read a lining once wet oil has reached it.
Why Seals Wear: Rubs at Start-Up
Stops and starts do the damage. NASA's 2006 review of turbomachinery sealing says labyrinth seals often take a permanent clearance increase from shaft excursions during stop and start and other transients. A rotor's vibration peaks as it passes through a critical speed, so that is when the shaft is most likely to find the teeth.
A rub also heats. In a Turbomachinery article on rubs, Richard Thomas of Metrix explains that friction can melt or weld the contacting surfaces, and that a rub always adds some local heat to the rotor, which bows it. In his example a hot restart tripped on high vibration while passing a critical speed, and the cause was a thermally bowed rotor. A bowed rotor tends to rub harder, which is how one rough start can damage several seals.
Two practical conclusions follow. First, follow the OEM start-up sequence for sealing steam, vacuum, turning gear and warm-up, because the sequence exists to avoid uneven heating. Second, where starts are frequent I would price an alternative to a plain labyrinth. The TurboCare article describes retractable packing, introduced in 1986, in which springs hold the segments open during start-up with a clearance of roughly 0.090 to 0.150 in (2.3 to 3.8 mm). Steam pressure closes them as flow builds, after the turbine has heated evenly and passed its critical speed.
Plain, High-Low, Honeycomb, Brush and Retractable: What Each Variant Does
Each variant tries to run a smaller gap without more rubbing.
Straight-through labyrinth. All the teeth stand at the same height over a plain surface. It is the simplest and cheapest, and a rub opens its clearance for good.
High-low (stepped) labyrinth. The teeth sit at alternating heights over a stepped surface, so the steam has to change direction as it passes, and less of the jet carries into the next gap. It usually costs more to machine, and differential expansion must not walk the teeth off their steps.
Honeycomb. The stator carries a honeycomb liner that the teeth can rub into. The Karlsruhe paper says honeycomb liners tolerate rubbing to a certain extent and so allow smaller gaps, which means less leakage. That paper studies aero engine seals, but the principle carries over: the liner takes the damage instead of the rotor.
Brush. A ring of fine bristles bears lightly on the shaft. The NASA review says brush seals have been used in industrial gas and steam turbines since the 1990s, usually with cobalt-based wire bristles, and that they ride through the shaft excursions that permanently open a labyrinth. It also cautions that steam turbine rotors can be sensitive to rubs because of uneven heating, so contact is not free of risk.
Retractable. Described above: the segments stay open through start-up and close when conditions allow.
On what these gain, be sceptical. The NASA review says brush seals can leak upwards of 50 percent less than labyrinth seals, but that describes the seal and not your turbine's output. Supplier output figures need more care. TurboCare credits most of a 3.6 percent rise in output against steam flow on a 444 MW unit to new retractable brush seals, yet the old packing there had typically been found about 0.025 in (0.64 mm) over a design clearance of the same size. The report does not separate the gain from the seal design from the gain of replacing worn packing. Ask for any promised gain to be tested before and after, and price a like-for-like kit alongside it.

The seal variants and what each one does. Source: Pumps & Systems (2016); Karlsruhe Institute of Technology (2019); Modern Power Systems (2000); NASA TM-2006-214341.
What Failing Seals Look Like: Symptoms and the First Checks
Seal wear rarely announces itself, and several symptoms have a cheaper cause than the rings. Check the system first.
Water in the lube oil. Gland steam leakage is the usual suspect. The gland system exists to keep steam from escaping along the shaft, so look at the exhauster vacuum and the gland condenser outlet temperature before blaming the rings. Then check the oil vapour extraction.
Vacuum loss with a clean condenser. The low pressure glands are under vacuum and rely on sealing steam to keep air out. If the header pressure is too low, air gets in. Check the header pressure and its control valve first, then the low pressure packing.
Steam at the glands. Steam escaping outside means the outer leak-off is not drawing hard enough, or the header pressure is too high, or the high pressure rings have worn until the leakage is more than the exhauster can take.
A leak-off valve that opens further than before. At higher loads the surplus from the high pressure seals dumps to the condenser through the leak-off valve. If that valve opens further than it used to at the same load, that points to the high pressure seals passing more. Trend its position.
Efficiency loss without a clear cause. Interstage and tip seal wear does not show at the glands at all. It shows as section efficiency drifting without deposits to explain it, which our article on common steam turbine failures lists among the early warnings, and which a steam path audit can attribute to individual seals once the casing is open.

Symptoms of seal wear and the cheaper causes to check first. Source: U.S. EPR Final Safety Analysis Report, section 10.4.3 (NRC); MIMAH engineering practice.
Replacing Seals: Measure the Clearances Before You Order the Kit
A seal kit can only be as good as the measurements behind it. Before anything is cleaned, record the as-found clearance at each ring, at the bottom, the top and both sides, and keep it with the as-left figures. Clearances that are tight at the bottom and open at the top say more about bearing wear and rotor position than about the rings.
Record the seal itself: number of teeth, tooth height and profile, ring segments, springs, material, and whether the strips are integral or caulked into grooves. If drawings exist, send them to the supplier with the measurements. If they do not, the ring can be measured and reproduced. That is reverse engineering, and it is often faster than waiting for an OEM part.
Look at what the seal runs against. Grooving, heat checking or a bowed shaft under the packing will defeat a new ring. Fix the cause of the rub as well as the rings. A kit that goes onto a rotor that still bows on a hot restart will rub again.
Finally, decide whether to restore or upgrade. A like-for-like kit is right for a machine that starts rarely and runs steadily. A retractable or brush design is worth pricing for a machine that starts often, or that has a record of rubbing in its first minutes. Seals have long lead times, so order against the likely scope, as our guide to steam turbine overhaul cost explains.
What to Do Next
If your turbine has rising gland leakage, water in the oil, or an efficiency trend you cannot explain, start with the gland steam system readings and compare them with last year at the same load. Then decide whether the seals can wait for the next outage, and put clearance measurement and a seal kit in that outage's scope.
MIMAH's rotating equipment team is independent of any one OEM, and our work includes performance diagnostics, component refurbishment and reverse engineering of critical spares. If you have seal clearances to measure, a kit to specify or a drawing that no longer exists, get in touch.